Please use this identifier to cite or link to this item: http://www.dspace.espol.edu.ec/handle/123456789/60728
Title: Rediseño de la Planta Depuradora de Aguas Residuales en la comunidad Santa María del Fiat - Olón
Authors: Merchán, Bethy , Director
Arteaga Bravo, Itatí Jamileth
Núñez Olmedo, Douglas Steven
Keywords: Depuración
Lodos activados
Carga contaminante
Rediseño
Issue Date: 2023
Publisher: ESPOL.FICT
Citation: Arteaga Bravo, I. J. y Núñez Olmedo, D. S. (2023). Rediseño de la Planta Depuradora de Aguas Residuales en la comunidad Santa María del Fiat-Olón. [Proyecto Integrador]. ESPOL.FICT .
Description: Las aguas residuales, producto de las actividades antropogénicas, representan un impacto ambiental crítico, que requiere supervisión y gestión adecuada. La comunidad Sta. María del Fiat tiene 1546 habitantes y descarga sus aguas residuales en una Planta Depuradora que funciona mediante un proceso de aireación. Esta planta presenta problemas de lodos flotantes en el tanque clarificador, posiblemente por escasa extracción de lodos mediante el caudal de purga. El objetivo de este proyecto es rediseñar la planta de lodos activados de la comunidad Santa María del Fiat mediante ensayos de laboratorio, análisis de operaciones y procesos unitarios para la optimización del sistema depurador. Los análisis realizados demostraron que la presencia de lodos en la superficie del clarificador influye en la calidad del efluente, presentando cargas contaminantes que sobrepasan los Límites Máximos Permisibles (LMP) indicados en el TULSMA (SST=303mg/L>130mg/L; DQO=254mg/L>200mg/L; Coliformes Fecales=54000>2000mg/L). De la misma forma las dimensiones del clarificador no son adecuadas para la correcta decantación de los lodos, es por ello, que se rediseñó un nuevo clarificador con dimensiones óptimas y su ubicación en la parte posterior de la planta actual (L=4.5m, A=2m, H=3.5m, Pendiente de tolva=60º). Se concluye que el caudal de purga desempeña un papel crucial para eliminar microorganismos filamentosos, controlando su proliferación y mejorando la eficiencia del proceso; este caudal debe ser de 0,77 m3 /d. Así mismo, la propuesta de la infraestructura de saneamiento adecuada contribuye con los Objetivos de Desarrollo Sostenible 3, 6, 11, 12, 13, 14, 15 y 17. Palabras Clave: Depuración, lodos activados, carga contaminante, rediseño
metadata.dc.description.abstractenglish: Wastewater, a product of anthropogenic activities, represents a critical environmental impact that requires monitoring and proper management. The community of Sta. María del Fiat has 1,546 inhabitants and discharges its wastewater to a wastewater treatment plant that operates by means of an aeration process. This plant has problems with floating sludge in the clarifier tank, possibly due to poor sludge removal through the purge flow. The objective of this project is to redesign the activated sludge plant of the Santa Maria del Fiat community by means of laboratory tests, operation analysis and unit processes for the optimization of the purification system. The analyses performed showed that the presence of sludge on the surface of the clarifier influences the quality of the effluent, presenting pollutant loads that exceed the Maximum Permissible Limits (MPL) indicated in the TULSMA (TSS=303mg/L>130mg/L; COD=254mg/L>200mg/L; Fecal Coliforms=54000>2000mg/L). Likewise, the dimensions of the clarifier are not adequate for the correct settling of the sludge; therefore, a new clarifier was redesigned with optimal dimensions and its location at the rear of the current plant (L=4.5m, W=2m, H=3.5m, hopper slope=60º). It is concluded that the purge flow rate plays a crucial role in eliminating filamentous microorganisms, controlling their proliferation and improving the efficiency of the process; this flow rate should be 0.77 m3 /d. Likewise, the proposal for adequate sanitation infrastructure contributes to Sustainable Development Goals 3, 6, 11, 12, 13, 14, 15 and 17. Keywords: Wastewater treatment, activated sludge, pollutant load, redesign
URI: http://www.dspace.espol.edu.ec/handle/123456789/60728
metadata.dc.identifier.codigoproyectointegrador: INGE-2268
Appears in Collections:Tesis de Ingeniería Civil

Files in This Item:
File SizeFormat 
T-114203 INGE-2270.pdf17.03 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.