Por favor, use este identificador para citar o enlazar este ítem: http://www.dspace.espol.edu.ec/handle/123456789/69025
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorSánchez Aguirre, Scarlet Gabriela-
dc.contributor.authorMata Puente, Rafael David-
dc.contributor.authorLeón Torres, Jonathan Roberto, Director-
dc.date.accessioned2026-06-12T17:15:47Z-
dc.date.available2026-06-12T17:15:47Z-
dc.date.issued2025-
dc.identifier.citationSánchez Aguirre S.G, Mata Puente R.D. (2025) Implementación de un simulador de señales fisiológicas para el laboratorio de Neurociencias y Bioingeniería [Proyecto Integrador] Escuela Superior Politécnica del Litoral. Guayaquil, 120 páginases_EC
dc.identifier.urihttp://www.dspace.espol.edu.ec/handle/123456789/69025-
dc.descriptionCONDICIONAMIENTO DE PUBLICACION DE PROYECTO. El presente proyecto desarrolla un simulador portátil de señales fisiológicas para entrenamiento en adquisición y procesamiento de señales biomédicas, respondiendo a la necesidad de herramientas educativas accesibles en instituciones de formación en salud. El objetivo es implementar un dispositivo que genere señales ECG, EMG y PPG con condiciones patológicas configurables mediante visualización táctil y salidas analógicas para equipos de adquisición. Se empleó un microcontrolador ESP32-WROOM-32 con frecuencia de muestreo de 2 kHz, modelos matemáticos validados, pantalla Nextion de 7 pulgadas y convertidor DAC de 8 bits con conectores BNC. El prototipo se fabricó mediante manufactura aditiva en PETG, integrando sistema de alimentación con autonomía superior a 5 horas. La validación espectral alcanzó fidelidad superior al 99% mediante análisis FFT, confirmando morfologías características de las patologías simuladas. El dispositivo permite transmisión inalámbrica WiFi a cuatro clientes simultáneos mediante aplicación web con visualización en tiempo real a 60 fps. El BioSignalSimulator Pro representa una alternativa económicamente viable y accesible frente a simuladores comerciales, manteniendo características técnicas competitivas. Se concluye que el sistema demuestra la viabilidad de desarrollar tecnología biomédica educativa de calidad con recursos limitados, democratizando el aprendizaje en procesamiento de señales fisiológicas en el contexto educativo ecuatoriano.es_EC
dc.description.abstractCONDITION FOR PUBLICATION OF PROJECT. This project develops a portable physiological signal simulator for training in biomedical signal acquisition and processing, addressing the need for accessible educational tools in health training institutions. The objective is to implement a device that generates ECG, EMG, and PPG signals with configurable pathological conditions through tactile visualization and analog outputs for acquisition equipment. An ESP32-WROOM-32 microcontroller with 2 kHz sampling frequency, validated mathematical models, a 7-inch Nextion display, and an 8-bit DAC converter with BNC connectors were employed. The prototype was manufactured using PETG additive manufacturing, integrating a power system with autonomy exceeding 5 hours. Spectral validation achieved fidelity above 99% through FFT analysis, confirming characteristic morphologies of simulated pathologies. The device enables WiFi wireless transmission to four simultaneous clients through a web application with real-time visualization at 60 fps. The BioSignalSimulator Pro represents an economically viable and accessible alternative to commercial simulators, maintaining competitive technical characteristics. It is concluded that the system demonstrates the feasibility of developing quality educational biomedical technology with limited resources, democratizing learning in physiological signal processing within the Ecuadorian educational context. Keywords: Biosimulator, ESP32, Electrocardiography, Electromyography, Photoplethysmographyes_EC
dc.publisherESPOL.FIMCPes_EC
dc.subjectBiosimuladores_EC
dc.subjectESP32es_EC
dc.subjectElectrocardiografíaes_EC
dc.subjectElectromiografíaes_EC
dc.subjectFotopletismografíaes_EC
dc.titleImplementación de un simulador de señales fisiológicas para el laboratorio de Neurociencias y Bioingenieríaes_EC
dc.typeThesises_EC
dc.identifier.codigoespolT-116208-
dc.identifier.codigoproyectointegradorINGE-3032-
Aparece en las colecciones: Tesis de Mecatrónica

Ficheros en este ítem:
Fichero Tamaño Formato  
T-116208 INGE-3032 MATA-SANCHEZ.pdf6.02 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.