| dc.contributor.author | Figueroa Osorio., Billy Joel | |
| dc.contributor.author | Lovaton Reyes, Félix de Jesús | |
| dc.contributor.author | Endara Vélez, Iván David, Director | |
| dc.date.accessioned | 2026-01-15T15:46:21Z | |
| dc.date.available | 2026-01-15T15:46:21Z | |
| dc.date.issued | 2025 | |
| dc.identifier.citation | Figueroa Osorio B.J; Lovaton Reyes F.J. (2025). Disparo controlado de líneas de transmisión para mantener la estabilidad en el SEP con la implementación de FACTS [Proyecto Integrador] Escuela Superior Politécnica del Litoral | es_EC |
| dc.identifier.uri | http://www.dspace.espol.edu.ec/handle/123456789/67290 | |
| dc.description | CONDICIONAMIENTO DE PUBLICACION DE PROYECTO. La pérdida de una línea de transmisión puede generar un desbalance en el sistema, ya que conlleva a una redistribución del flujo de potencia. Aunque el sistema eléctrico de Potencia debe estar diseñado para soportar estas contingencias, en un sistema de transmisión de doble circuito, la línea de respaldo está dimensionada para soportar la carga completa que antes fluía por ambas líneas de manera equitativa, hasta que se restablezca la línea que se abrió por alguna falla. Sin embargo, el SEP no está exento de que esto ocurra; la sobrecarga asumida por la línea de respaldo puede ser tan alta que provoque su apertura, desencadenando efectos en cascada y llevando al sistema a niveles críticos de estabilidad, incluso a un blackout. Para estos casos, las protecciones de la línea actúan en tiempos muy cortos, y con la ayuda de un SVC, cuya inyección de potencia reactiva permite nivelar los perfiles de tensión en las barras y aumentar la cargabilidad de las líneas, se obtiene un lapso de tiempo que facilita la toma de decisiones para mantener mi sistema de Potencia operativo. En futuros trabajos, se plantea aplicar una protección sistemática basada en deslastres de carga, con el fin de mantener la estabilidad del sistema y evitar su colapso, considerando criterios de prioridad para determinar qué cargas se deben mantener, como hospitales, laboratorios, entre otros. | es_EC |
| dc.description.abstract | CONDITION FOR PUBLICATION OF PROJECT. loss of a transmission line can generate an imbalance in the system, as it leads to a redistribution of power flow. Although the power system must be designed to withstand such contingencies, in a double-circuit transmission system, the backup line is sized to support the full load that previously flowed through both lines equally, until the line that tripped due to a fault is restored. However, the EPS is not exempt from this situation; the overload taken on by the backup line may be so high that it causes its own tripping, triggering cascading effects and driving the system to critical stability levels, even to a blackout. In such cases, line protections operate within very short timeframes, and with the support of an SVC, whose injection of reactive power helps level the voltage profiles at the buses and increase the loadability of the lines, an additional time window is gained that facilitates decision-making to keep the power system operational. In future work, it is proposed to apply a systematic protection scheme based on load shedding, in order to maintain system stability and prevent collapse, considering priority criteria to determine which loads should be preserved, such as hospitals, laboratories, and others. Keywords: SEP (Power System), SVC, BLACKOUT, Overloads, Transmission Lines. | es_EC |
| dc.publisher | ESPOL.FIEC | es_EC |
| dc.subject | SEP (Sistema Eléctrico de Potencia) | es_EC |
| dc.subject | SVC | es_EC |
| dc.subject | blackout | es_EC |
| dc.subject | sobrecargas | es_EC |
| dc.subject | líneas de Transmisión | es_EC |
| dc.title | Disparo controlado de líneas de transmisión para mantener la estabilidad en el SEP con la implementación de FACTS. | es_EC |
| dc.type | Thesis | es_EC |