Por favor, use este identificador para citar o enlazar este ítem: http://www.dspace.espol.edu.ec/handle/123456789/65862
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorVega Lozano, José Luis-
dc.contributor.authorSantos Baquerizo, Eduardo, Director-
dc.date.accessioned2025-04-28T18:33:46Z-
dc.date.available2025-04-28T18:33:46Z-
dc.date.issued2025-02-05-
dc.identifier.citationVega Lozano J.L. (2024). Rehabilitación de columnas fisuradas de hormigón armado aplicando varias soluciones, en un edificio de la Ciudad de Guayaquil, Ecuador. [Proyecto de Graduación]. Escuela Superior Politécnica del Litoral.es_EC
dc.identifier.urihttp://www.dspace.espol.edu.ec/handle/123456789/65862-
dc.descriptionLa rehabilitación de una edificación es fundamental para garantizar la seguridad de la estructura y de sus habitantes. En la ciudad de Guayaquil se realiza el estudio a las columnas de la segunda planta alta de una Edificación que ha estado expuesta al medio ambiente por muchos años llevándola al deterioro de sus elementos estructurales, donde se analiza las soluciones técnicas para la rehabilitación. Se realizaron ensayos destructivos y no destructivos a los elementos estructurales en análisis, también se realizó el levantamiento de información, inspección visual en cada columna donde se pudo constatar con claridad el estado actual de la edificación, con esto se pudo proponer las soluciones técnicas de rehabilitación como lo son el método del encamisado con hormigón armado y el método de la Fibra de Carbono este como método de solución sostenible. En el análisis realizado se pudo obtener datos correctos del estado actual de la Edificación como lo son la resistencia del hormigón, así como también la cuantía de acero existente, espesores de recubrimiento, estado del acero de refuerzo. Con las soluciones propuestas para la rehabilitación garantizamos la seguridad de la estructura y la de los usuarios que la habitan.es_EC
dc.description.abstractThe rehabilitation of a building is essential to guarantee the safety of the structure and its inhabitants. In the city of Guayaquil, a study is carried out on the columns of the second upper floor of a building that has been exposed to the environment for many years, leading to the deterioration of its structural elements, where the technical solutions for rehabilitation are analyzed. Destructive and non-destructive tests were carried out on the structural elements under analysis, information gathering was also carried out, visual inspection on each column where the current state of the building could be clearly verified, with this it was possible to propose technical rehabilitation solutions. such as the reinforced concrete cladding method and the Carbon Fiber method, this as a sustainable solution method. In the analysis carried out, it was possible to obtain correct data on the current state of the Building, such as the strength of the concrete, as well as the amount of existing steel, coating thicknesses, and state of the reinforcing steel. With the solutions proposed for the rehabilitation we guarantee the safety of the structure and that of the users who inhabit it. Keywords: Rehabilitation, Security, Sustainability, Building.es_EC
dc.language.isoeses_EC
dc.publisherESPOL.FICTes_EC
dc.subjectRehabilitaciónes_EC
dc.subjectSeguridades_EC
dc.subjectSostenibilidades_EC
dc.subjectEdificaciónes_EC
dc.titleRehabilitación de columnas fisuradas de hormigón armado aplicando varias soluciones, en un edificio de la Ciudad de Guayaquil, Ecuadores_EC
dc.typeThesises_EC
dc.identifier.codigoespolT-115156-
dc.identifier.codigoproyectointegradorPOSTG151-
Aparece en las colecciones: Tesis de Maestría en Ingeniería Civil