Por favor, use este identificador para citar o enlazar este ítem: http://www.dspace.espol.edu.ec/handle/123456789/68403
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorLindao Farías, Álvaro Mauricio-
dc.contributor.authorZambrano Loor, Henrry Patricio-
dc.contributor.authorFalquez Torres, Daniel Andrés, Director-
dc.date.accessioned2026-05-22T16:47:50Z-
dc.date.available2026-05-22T16:47:50Z-
dc.date.issued2026-
dc.identifier.citationLindao Farías A.M, Zambrano Loor H.P. (2026) Caracterización Geotécnica del deposito de arcillas en planicie de inundación de Samborondón mediante la integración de ensayos de campo y laboratorio [Tesis Maestría] Escuela Superior Politécnica del Litoral. Guayaquil, 151 páginases_EC
dc.identifier.urihttp://www.dspace.espol.edu.ec/handle/123456789/68403-
dc.descriptionLas arcillas ubicadas permanentemente bajo nivel freático cuya humedad natural supera el límite líquido representan un desafío para la correcta cimentación de proyectos de cualquier índole y si adicional a este estado de saturación se agrega un comportamiento sensitivo, el caso representa un caso de estudio interesante. Dada la gran extensión de la planicie donde se encuentran estas arcillas, se propone caracterizar parte del depósito implementando métodos de campo usuales como el sondeo mecánico SPT, geofísica MASW y la determinación de las propiedades índice mediante ensayos rutinarios de laboratorio, haciendo especial énfasis en la determinación del límite líquido mediante el equipo de caída de cono según la norma BS 1377: Part 2 : 1990 (British Standards Institution, 1990). Dicha norma también nos permite tomar la medida indirecta de resistencia al corte en muestras inalteradas y alteradas de arcilla. Finalmente se detectó un grado de sensitividad de al menos un 23% y variaciones entre el límite líquido determinado mediante el dispositivo de límite líquido y el aparato de caída de cono.es_EC
dc.description.abstractClays permanently located below the groundwater table, whose natural water content exceeds the liquid limit, represent a challenge for the proper foundation of engineering projects of any kind. When this saturated condition is combined with sensitive behavior, the situation becomes an interesting case study.Given the large extent of the floodplain where these clays are found, it is proposed to characterize part of the deposit by implementing common field methods such as mechanical drilling with the Standard Penetration Test (SPT), MASW geophysical surveys, and the determination of index properties through routine laboratory tests. Special emphasis is placed on the determination of the liquid limit using the fall cone apparatus in accordance with BS 1377: Part 2: 1990 (British Standards Institution, 1990).This standard also allows for the indirect measurement of undrained shear strength in both undisturbed and remolded clay samples. Finally, a degree of sensitivity of at least 23% was identified, along with variations between the liquid limit values obtained using the Casagrande device and the fall cone apparatus. Keywords: Clay, sensitivity, liquid limit, fall cone.es_EC
dc.publisherESPOL.FICTes_EC
dc.subjectArcillaes_EC
dc.subjectSensitividades_EC
dc.subjectLímite líquidoes_EC
dc.subjectCaída de conoes_EC
dc.titleCaracterización Geotécnica del deposito de arcillas en planicie de inundación de Samborondón mediante la integración de ensayos de campo y laboratorioes_EC
dc.typeThesises_EC
dc.identifier.codigoespolT-116071-
dc.identifier.codigoPOSTG222-
Aparece en las colecciones: Tesis de Maestría en Geotecnia

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
T-116071 POSTG222 Lindao-Zambrano.pdf8.08 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.