dc.contributor.author Garcés Nevárez, José Andrés
dc.contributor.author Cagua Pérez, Stalyn Jonás
dc.contributor.author Martínez Lozano, Ernesto Rolando, Director
dc.date.accessioned 2026-02-20T19:11:01Z
dc.date.available 2026-02-20T19:11:01Z
dc.date.issued 2025
dc.identifier.citation Garcés Nevárez J.A; Cagua Pérez S.J. (2025) Repotenciación de la línea de distribución de vapor a marmitas de un centro hospitalario [Proyecto Integrador] Escuela Superior Politécnica del Litoral es_EC
dc.identifier.uri http://www.dspace.espol.edu.ec/handle/123456789/67765
dc.description El sistema de distribución de vapor que alimenta a ocho marmitas industriales del área de cocina en una institución hospitalaria de Guayaquil ha estado en funcionamiento por más de 30 años, superando su rango de vida útil. Se evidencia un aumento progresivo del consumo de GLP debido al creciente deterioro del sistema y dada la problemática se presenta la necesidad de realizar el diseño técnico de ingeniería para su repotenciación. Se trabajó con metodologías que comprenden el diagnóstico energético del sistema, propuesta de repotenciación, comparación de los cambios proyectados, y la evaluación económica de la propuesta. Los resultados demostraron que el 10% del vapor producido por la caldera se desperdicia en fugas y en la línea de distribución por la ineficacia del aislamiento o la ausencia del mismo. Se realizó la propuesta en la cual se detalló las especificaciones técnicas de las tuberías, regulador de presión, aislamiento térmico, y demás componentes necesarios para la repotenciación. Se proyecta que en caso de que instituto hospitalario la implemente aumente su eficiencia en un 24.3%, reduzca el consumo de GLP en 4 kg/h, lo que conllevaría a un a ahorro anual de 1209.60 USD. Se estima que el costo de implementación sea alrededor de 3629.13 USD, por lo que se estima un retorno de inversión de 3 años. es_EC
dc.description.abstract The steam distribution system that supplies eight industrial kettles in the kitchen area of a hospital institution in Guayaquil has been in operation for more than 30 years, exceeding its service life. A progressive increase in LPG consumption has been observed due to the system’s deterioration, which raises the need to carry out the engineering design for its repowering. The methodology included the energy diagnosis of the system, the repowering proposal, the comparison of projected changes, and the economic evaluation. Results showed that 10% of the steam produced by the boiler is wasted through leaks and in the distribution line due to ineffective or missing insulation. The proposal detailed the technical specifications of piping, pressure regulator, thermal insulation, and other necessary components for repowering. It is projected that, if implemented by the hospital, the system efficiency would increase by 24.3%, reducing LPG consumption by 4 kg/h, leading to an annual saving of USD 1,209.60. The implementation cost is estimated at approximately USD 3,629.13, with a projected return on investment of three years. Keywords: Repowering, Steam-jacketed kettles, efficiency, LPG consumption, return on investment. es_EC
dc.publisher ESPOL.FIMCP es_EC
dc.subject Repotenciación es_EC
dc.subject Marmitas es_EC
dc.subject Eficiencia es_EC
dc.subject Consumo de GLP es_EC
dc.subject Retorno de inversión es_EC
dc.title Repotenciación de la línea de distribución de vapor a marmitas de un centro hospitalario es_EC
dc.type Thesis es_EC
dc.identifier.codigoespol T-115702
dc.identifier.codigoproyectointegrador INGE-2945