DSpace Repository

Diseño sismo-resistente de un edificio de 4 pisos localizado en la ciudad de Manta

Show simple item record

dc.contributor.author Borbor Alvia, Romina Valentina
dc.contributor.author Vera Baque, Allisson Nicole
dc.contributor.author Rojas Cruz, Pedro Pablo, Director
dc.date.accessioned 2026-03-23T14:53:44Z
dc.date.available 2026-03-23T14:53:44Z
dc.date.issued 2025
dc.identifier.citation Borbor Alvia R.V; Vera Baque A.N (2025) Diseño sismo-resistente de un edificio de 4 pisos localizado en la ciudad de Manta [Proyecto Integrador] Escuela Superior Politécnica del Litoral es_EC
dc.identifier.uri http://www.dspace.espol.edu.ec/handle/123456789/67972
dc.description Este proyecto evaluó el desempeño estructural y económico de dos sistemas sismorresistentes para un edificio de 4 pisos en Manta. Se comparó la mampostería confinada modelada como puntales (según ASCE 41-17) con un sistema de mampostería aislada (donde se considera solo como carga muerta). El análisis mediante software de elementos finitos bajo las normas NEC-SE-DS y ACI 318-19 demostró que solo el segundo modelo cumplió con los límites de deriva. En contraste, la alternativa con aisladores sísmicos resultó ser 7.11% más económica que el sistema modelado con diagonales a compresión. Se concluye que el sistema con mampostería aislada ofrece la mejor relación costo-beneficio para este caso específico, aunque el modelado con diagonales resulta esencial para comprender el comportamiento estructural real. es_EC
dc.description.abstract This project assessed the structural and economic performance of two seismic-resistant systems for a four-story building in Manta. A comparative analysis was conducted between confined masonry modelled using diagonal struts (in accordance with ASCE 41-17) and an isolated masonry system, wherein the masonry is treated solely as dead load. Finite element analysis performed under the NEC-SE-DS and ACI 318-19 standards demonstrated that only the latter model complied with the allowable drift limits. The alternative utilising seismic isolation exhibited a 7.11% reduction in cost compared to the strut-modelled system. It is concluded that the isolated masonry system offers a superior cost-benefit ratio for this specific application, although the strut-based modelling methodology remains essential for comprehending the actual structural behaviour. Keywords: Masonry, modelling, struts, seismic, isolator es_EC
dc.publisher ESPOL.FICT es_EC
dc.subject Mampostería es_EC
dc.subject Aislador es_EC
dc.subject Modelado es_EC
dc.subject Puntales es_EC
dc.subject Sísmico es_EC
dc.title Diseño sismo-resistente de un edificio de 4 pisos localizado en la ciudad de Manta es_EC
dc.type Thesis es_EC
dc.identifier.codigoespol T-115855
dc.identifier.codigoproyectointegrador INGE-2894


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account